株式会社福原精机制作所|全球第一占有率的在神户生产的圆筒针织机(简称大圆机)制造商

Revision History of Software for AZ FCP60 Machine Control Panel

Ver4.00 4.00 or later

Version No.DateContents
V4.37 4.03
2020/2
Fixed:
 1) New servo ACT.

V4.33 4.03

2019/8
Fixed:
 1) Op.relay (filter flow) buttom.
 2) Display servo error.

V4.32 4.03

2019/7
Fixed:
 1) Screen white.

V4.31 4.03

2019/7
Add:
 1) Servo act back reverse.
 2) Filter flow.
 3) FMA(remote).
Fixed:
 1) MINAS-A6 initial value.

V4.30 4.03

2019/5
Add:
 1) OD6.

V4.29 4.03

2019/4
Fixed:
 1) LGL.
Fixed:
 1) Servo error display for monitoring.

V4.28 4.02

2019/3
Add:
 1) Add OD7.
 2) Add voltage selection at inverter initial.

V4.27 4.02

2019/2
Fixed:
 1) Screen freezing.

V4.26 4.02

2019/1
Fixed:
 1) Screen display when Power-on. (Ver4.25)
 2) Error icon. (Ver4.25)
 3) Striper take-off.(Ver4.26)

V4.24 4.02

2018/11
Fixed:
 1) Chinese message. (Ver4.23 4.02)
 2) Auto oiler. (Ver4.23 4.02)
Fixed:
 1) Calculator. (Ver4.24 4.02)

V4.22 4.02

2018/11/14
Fixed:
 1) Respond to PING. (Ver4.20 4.02P)
 2) Fixed Italian error messege. (Ver4.21 4.02P)
 3) Fixed Italian message. (Pege 31) (Ver4.22 4.02)

V4.19 4.01

2018/09/18
Fixed:
 1) Fixed auto oiler.

V4.18 4.01

2018/09/18
Fixed:
 1) Fixed error “Course data cannot be acquired” When loading big size pattern.

V4.16 4.01

2018/09/18
Fixed:
 1) Fixed screen freezing When loading pattern. (Big size pattern)

V4.14 4.01

2018/07/11
Fixed:
 1) Fixed screen freezing When loading pattern. (Combination of new CPU and old LCD)

V4.13 4.01

2018/05/07
Fixed:
 1) Fixed screen freezing when entering “.” When loading pattern.
Add:
 1) Added check-up notification function.

V4.08 4.01

2017/09/04
Fixed:
 1) Fixed a problem that servo take-up changed from position mode to torque mode irrespective of the choice when changing the needle mode of the electric pattern machine.
 2) When updating the servo take-up mode, update the numerical value of the winding icon.

V4.07 4.01

2017/08/16
Change:
 1) Do not issue the placer data entry screen for models without placers in creating striper data.

V4.06 4.01

2017/07/24
Fixed:
 1) Fixed the actuator check at the time of “RESET” the striper machine.

V4.05 4.01

2017/07/04
Fixed:
 1) After turning on the power, wait a few seconds before displaying the screen.
 2) Improved communication instability with FMC (CAN communication changed).

V4.04 4.01

2017/07/01
Fixed:
 1) After “RESET” on EK machine, communication with the FMC becomes unstable, so wait a while after “RESET”.

Below Ver4.00 4.00

Version No.DateContents

V3.25 3.25

2018/11/14
Fixed:
 1) Fixed Italian message.

V3.24 3.24

2018/09/19
Fixed:
 1) Fixed auto oiler.

V3.22 3.22

2017/03/22
Fixed:
 1) Striper finger letter break.
Add:
 1) OD6B.
 2) Electric machine data correction.
 3) Select screen to correct in a normal mode at the time of striper reset.

V3.21 3.21

2017/02/10
Fixed:
 1) Dial feeder adjust function.
 2) Expand “OD5 SGEAR” set range to 60.
Delete:
 1) Servo take-up encoder error detection function.

V3.20 3.20

2017/02/10
Changed:
 1) Setting window of the servo take-up.
Fixed:
 1) Subdirectory is strage at the time of a parameter data change.
 2) Garment machine.

V3.17 3.17

2017/02/10
Changed:
 1) LAP.
Fixed:
 1) Fixed feeder in the electric pattern test mode.

V3.14 3.1L

2016/07/14
Fixed:
 1) Guide roll movement-style TAKE UP device communication error.

V3.14 3.13

2016/05/31
Add:
 1) Quarter gauge functions to a yarn length meter.
 2) “MPF” and “MPF-P(S)” and “MPF-P(D)” to a yarn length meter.
 3) Indication to promote a “RESEDT PARAMETER” in electric pattern knit.

V3.13 3.12

2016/05/31
Fixed:
 1) In the case of 45, 46, 47, a take up value is an error in “GATE” on in “SERVO LAP” mode time.

V3.12 3.11

2016/03/14
Fixed:
 1) The dial side does not contain pattern data more than 6M byte.

V3.11 3.11

2016/03/09
Add:
 1) Lamp lighting at the time of the machine stop. 2) PSG input on the dial side.
Fixed:
 1) Of the guide roll is mobile; shake it off and is initialized the device.
 2) A value of the setting of the stop position delay line is increased by 100-fold when I perform reading of a value of the setting again.

V3.10 3.10

2015/12/16
Changed:
 1) Speed 8Mhz of the expansion interface (heat measures of the machine Control Panel).
Fixed:
 1) Panel freezes at the time of the LIST FILE select of the electric pattern.
 2) Malfunction when there is a gate more than two with a striper machine.

V3.05 3.05

2015/12/16
Add:
 1) LAN function of FMC50.

V3.04 3.04

2015/07/27
Add:
 1) 3.2FY3RE 26″.
Fixed:
 1) Striper data error occurs even if I make striper data in a version after “Ver 1.32 1.32 “ definitely.

V3.03 3.03

2015/07/21
Fixed:
 1) Take-up mode is the machine, and power supply ON and a timing of the gate switch pressing cannot detect “TAKEUP” error at same time.

V3.02 3.02

2015/06/24
Add:
 1) Takeiup motor of “IE3”.

V3.01 3.01

2015/05/24
Add:
 1) OD5 high leg take-up.
 2) “NEEDLESW” extension.
Fixed:
 1) At the time of the “NEEDLE” key operation, the screen except the main screen is displayed by the front.

V3.00 3.00

2015/04/24
Add:
 1) Electronic jacquard machine.
 2) Take-up motor for 7.5KW.

V1.36 1.41

2015/04/24
Changed:
 1) Change the SPI pin to 8MA or 2MA to let you distinguish a CPU board.

V1.35 1.38

2014/12/24
Add:
 1) Auto Doffer.
 2) OD5 take-up.

V1.31 1.30

2014/07/28
Changed:
 1) If a total course input value and total course values of “STRIPER DATA” are different, display error message.

V1.30 1.30

2014/07/28
Fixed:
 1) Communication error in gate ON which is the new type servo-motorized lapping take-up device.
 2) Inconvenience of the password less than eight columns.
 3) 2 last feeders at the time of the reset practice just after the “KNIT” practice work after “KNIT” practice in machine model “RSY3RE”.

V1.28 1.29

2014/06/02
Add:
 1) Speed control functions for a striper function.
 2) Spandex yarn forwarding function.
 3) Individual password function.
 4) Language in Portugal.Fixed: 1) When the panel is pushed in a striper mode, it does not start.
 2) ACSS function.
 3) Noise measures of the memory clear.

V1.25 1.25

2013/09/09
Add:
 1) The inch is displayed by thread head meter indication, too.
Changed:
 1) Handling of “RPM” cancellation mean at the time of change of the value.
 2) A stop lamp turns on at the time of state of “FALL OUT”.
 3) Memory capacity to store at the time of a blackout from 30KB to 20KB.
 4) Reaction improvement of the change screen of the value of “RPM”.
 5) Up to 999 of maximum speed restrictions.

V1.22 1.23

2013/08/01
Fixed:
 1)Phenomenon not to rarely save data at the time of power supply interception.

V1.22 1.22

2013/07/03
Fixed:
 1)The top and bottom key in “FINGER INFO” becomes invalid when enter “STRIPER TEST MODE” once.
Changed: 
1) Initialization routine of “NVRAM”.
 2) Movement of “STRIPER SIMULATION MODE 1”.
 3) Indication method of the “STRIPER” menu.
 4) Control of “Lapping Take-up”.

V1.21 1.21

2013/06/13
Fixed:
 1) When, in Japanese which there is the case that letter indication is twisted with screen, “AUTO OILER” is chosen.

V1.20 1.21

2013/06/04
Added:
 1) Noise takes measures at the time of “NEEDLE PROTECTON” error outbreak.

V1.20 1.20

2013/06/03
Fixed:
 1) Now compatible with the Striper machine.
 2) The phenomenon that a value of the setting frequency rarely changes
      itself into at the time of the change of the RPM level.

V1.11 1.13

2013/05/15
Fixed:
 1) Sensor mistake of the “F4” fuse error.

V1.11 1.12

2013/04/25
Fixed:
 1) Battery RAM error measures at the time of the start of the machine.

V1.11 1.11

2013/04/18
Fixed:
 1) Battery RAM error measures at the time of the start of the machine.

V1.10 1.10

2013/03/13
Fixed:
 1) Icon message for English sentences compactly.
Changed:
 1) Enlarged the monitoring space of the error “YFD IN” and “YFD OUT”.
 2) Supported “ACT7” to a servomotor take-up menu.
Changed:
 1) Speed factor indication.

V1.03 1.03

2013/03/06
Fixed:
 1) Delete the garbage of the stop factor of the machine at the time of software start.
 2) Publish a preservation order after inverter initialization processing.
 3) Servo error sometimes revises a displayed problem at the time of the change of the RPM level.
 4) The issue of communication noise with the interface board.
Changed:
 1) The upper limit of the RPM count to 120The upper limit of the RPM count to 120.
 2) The indication space of the display is changed to 250ms by 500ms.
 3) 0 input is possible in RPM.

V1.02 1.01

2012/04/17
Fixed:
It takes a long time to show the stop factor after pressing the “STOP FACTOR” button when using
Mechanical Take-up.

Revision History of Software for AZ FCP70 Machine Control Panel

Version No.DateContents
V1.30 1.19
2018/10/31
Fix: 
1) RPM Display. (EUT-220)

V1.29 1.18

2018/08/16
Fix: 
1) FMC40 can not be installed.

V1.28 1.18

2018/08/16
Add: 
1) EUT-220

V1.27 1.17

2017/08/01
Add: 
1) FMC50

V1.26 1.16

2017/02/13
Fixed: 
1) Language in Portugal.
2) Parameter data correction.

V1.25 1.16

2017/02/13
Fixed: 
1) Electric pattern page “28” correction.

V1.24 1.16

2017/02/13
Fixed: 
1) File correction of the language.
2) Combination of Striper board and FDC boards of the FMC control.

V1.23 1.15

2017/02/13
Fixed: 
1) Machine data gate position for the striper machine.

V1.22 1.15

2017/02/13
Fixed: 
1) Check the number of the feeders and the number of the actuators at the time of pattern data transmission.
2) Communication with FMC using the USB interface.

V1.20 1.13

2016/01/08
Fixed: 
1) After setting test pattern by electronic jacquard machine, a pattern on the dial side is not stored.

V1.19 1.13

2016/01/08
Fixed: 
1) When the power supply of the machine is turned on, it becomes power supply OFF of the striper drive board.

V1.18 1.12

2016/01/08
Fixed: 
1) The making of the parameter and indication and a correction are not possible by electronic jacquard machine.

V1.07 1.07

2013/07/02
Fixed: 
1) Striper control of FMC to perform via a striper drive board.

V1.04 1.04

2013/06/04
Fixed: 
1) The malfunction that a screen hardens when I stop it during pattern data transmission with an electric mode.

V1.03 1.03

2013/05/21
Changed: 
1) The upper limit of the number of the repeat of striper data from 256 to 15000.
Fixed: 
1) The set point of the takeoff feeder is resettable.

V1.02 1.02

2013/05/21
Fixed: 
1) Time extension detective for prevention of mistakenly detective prevention of the “F4 FUSE ERROR”.
 2) Adjustment of the communication timing between the CPU.

V1.01 1.01

2013/05/08
Changed: 
1) Port electric current “NVRAM” “SSI” is changed to “2MA”.